摘要:本文研究TN系統(tǒng)常見(jiàn)故障及防范措施,主要分析:(1)當(dāng)三相設(shè)備發(fā)生單相碰殼故障時(shí),PEN線(xiàn)因某種原因斷開(kāi)或設(shè)備外殼接零線(xiàn)斷裂、虛接、未接時(shí)主要故障及采取的防范措施(2)三相負(fù)荷不對(duì)稱(chēng),PEN線(xiàn)斷開(kāi)或有PEN線(xiàn)但三相負(fù)荷不對(duì)稱(chēng)、三相負(fù)荷性質(zhì)不同時(shí),主要故障及采取的防范措施。 關(guān)鍵詞:接地;接零;系統(tǒng);故障;措施TNsystemfrequentlyseesamalfunctionandkeepswatchmeasureGaoLaiMingWangRuiYun(HebeisourcesofenergyoccupationTec,HebeiTangshan063004)Abstract:ThemalfunctionandcountermeasuresstudyingTNsystemiscommon,analysethemainbodyofabookmainly:Themainmalfunctionandthecountermeasures(1)Whilesingle-phasebumpagainstshellfailurehappenedinthree-phaseequipment,thePENlinedisconnectsthemainmalfunctionandthecountermeasuresadoptingbecauseofsomespeciescauseortheequipmentoutercoveringtakesoverwhenthenulllinebreaks,emptinessmeets,doesnotmeet(2)Three-phaseloadisasymmetric,disconnectthePENlinebutthree-phaseloadorthereisinthePENlinenosymmetrically,three-phaseloadnosimultaneous,mainmalfunctionofcharacterandthecountermeasuresadoptingKeywords:Groundconnection;Connecttoneutral;System;Malfunction;Measure1、引言:低壓配電系統(tǒng)可分為T(mén)N系統(tǒng)、TT系統(tǒng)、和IT系統(tǒng)三大類(lèi)。TN系統(tǒng)屬于中性點(diǎn)直接接地的保護(hù)接零系統(tǒng),它分為T(mén)N-C系統(tǒng)、TN-S系統(tǒng)、TN-C-S系統(tǒng)。本文僅分析TN-C系統(tǒng)常見(jiàn)故障及防范措施.TN-C系統(tǒng)為三相四線(xiàn)制供電方式,如圖一。其電源中性點(diǎn)引出一條PEN線(xiàn),其中設(shè)備的外殼接零線(xiàn)引到PEN線(xiàn)上,此系統(tǒng)由于N線(xiàn)與PE線(xiàn)合二為一,從而可節(jié)省導(dǎo)線(xiàn)材料,比較經(jīng)濟(jì)。在無(wú)特殊條件下,當(dāng)發(fā)生單相電源碰殼故障時(shí),泄漏電流將經(jīng)設(shè)備外殼引至PEN線(xiàn)導(dǎo)入大地,此時(shí),當(dāng)有人觸摸漏電設(shè)備外殼時(shí),由于工作接地電阻一般很小約2-4歐,而人身電阻很大,在最不利情況下,人體電阻約1000-2000歐,其值遠(yuǎn)遠(yuǎn)大于工作接地電阻,因分流作用,流過(guò)人體的電流很小,不足以對(duì)人構(gòu)成威脅,但當(dāng)下列幾種情況時(shí),應(yīng)值得注意。2、PEN線(xiàn)因某種原因斷開(kāi)時(shí),可能引起如下事故:2.1在三相負(fù)荷基本對(duì)稱(chēng)且負(fù)荷性質(zhì)基本相同時(shí)當(dāng)某臺(tái)設(shè)備、某相發(fā)生單相碰殼事故,其泄露電流將無(wú)通路。則故障設(shè)備與非故障設(shè)備間,將會(huì)出現(xiàn)不等電位,引起非故障設(shè)備外殼帶電現(xiàn)象,在易燃易爆危險(xiǎn)場(chǎng)所將是很危險(xiǎn)的。2.2在三相負(fù)荷不對(duì)稱(chēng),負(fù)荷性質(zhì)基本相同時(shí)當(dāng)PEN線(xiàn)斷開(kāi)時(shí),利用節(jié)點(diǎn)法可得PEN線(xiàn)的電壓為嚴(yán)重不平衡,三相相位嚴(yán)重不對(duì)稱(chēng),如圖三。嚴(yán)重威脅設(shè)備的正常運(yùn)行,甚至燒毀用電設(shè)備。綜上分析,應(yīng)采取如下有效措施(1)在不對(duì)稱(chēng)負(fù)載下,設(shè)備運(yùn)行必須保證PEN線(xiàn)不能斷開(kāi),中性點(diǎn)不會(huì)發(fā)生位移。PEN線(xiàn)要符合設(shè)計(jì)要求,要有足夠的機(jī)械強(qiáng)度,且阻抗要小(2)PEN線(xiàn)上不允許接開(kāi)關(guān)或熔斷器,以防當(dāng)開(kāi)關(guān)打開(kāi)或熔斷器熔絲熔斷后,人為造成斷開(kāi)PEN線(xiàn)。(3)PEN線(xiàn)上應(yīng)在多點(diǎn)處進(jìn)行必要的重復(fù)接地,以防某點(diǎn)重復(fù)接地失效后其它重復(fù)接地點(diǎn),仍能保證有接地,可以有效解決故障設(shè)備與非故障設(shè)備間發(fā)生不等電位,避免非故障設(shè)備外殼帶電問(wèn)題。(4)PEN線(xiàn)上不能有接點(diǎn),以防接點(diǎn)處因接觸電阻增大而發(fā)熱引起燒斷PEN線(xiàn)。PEN線(xiàn)截面應(yīng)與相線(xiàn)截面相同或相近,保證足夠的不對(duì)稱(chēng)下的負(fù)荷載流量3、有PEN線(xiàn)時(shí)的幾種特殊情況。3.1當(dāng)用電設(shè)備外殼接零線(xiàn)斷裂、虛接或未接時(shí)。發(fā)生一相碰殼,其泄漏電流將會(huì)直接導(dǎo)入大地,相當(dāng)于火線(xiàn)直接對(duì)地短路,而造成廠區(qū)內(nèi)所有金屬物件、設(shè)備設(shè)施(包括各種金屬管道、容器)都將會(huì)帶電。當(dāng)人觸摸帶電設(shè)備時(shí),人將承受的電壓為相電壓,流過(guò)人體的電流約為220mA,遠(yuǎn)遠(yuǎn)大于致命電流50mA,對(duì)人構(gòu)成重大威脅;當(dāng)虛接打火,在易燃易爆生產(chǎn)、經(jīng)營(yíng)場(chǎng)所則更為危險(xiǎn),易引發(fā)重大事故的發(fā)生,這是絕對(duì)不允許的。采取的措施是:(1)在供配電線(xiàn)路上,必須安裝具有漏電保護(hù)的開(kāi)關(guān),如DZL自動(dòng)空氣開(kāi)關(guān),以防發(fā)生此類(lèi)故障時(shí)能可靠跳閘,從而保障人身安全和設(shè)備設(shè)施安全。(2)用電設(shè)備外殼接零線(xiàn)的接點(diǎn)必須聯(lián)結(jié)牢固可靠,一般可采用壓接或焊接方式,并應(yīng)定期檢修、測(cè)試,以保證供電運(yùn)行的可靠性和安全性。3.2三相負(fù)荷不對(duì)稱(chēng)。三相電流矢量和不等于零,即,則流過(guò)PEN線(xiàn)中的電流不等于零,可能出現(xiàn)如下問(wèn)題:(1)三相負(fù)荷不對(duì)稱(chēng),三相負(fù)荷性質(zhì)基本相同時(shí),如圖四看出,PEN線(xiàn)的電流很大,有時(shí)用數(shù)字電筆測(cè)出的值比相線(xiàn)的值都大。這將造成PEN線(xiàn)與用電設(shè)備間出現(xiàn)不等電位。在無(wú)故障情況下,用電設(shè)備外殼仍然發(fā)生帶電現(xiàn)象,這在危險(xiǎn)環(huán)境和場(chǎng)所中是絕對(duì)不允許的。(2)三相負(fù)荷不對(duì)稱(chēng),三相負(fù)荷性質(zhì)不相同時(shí),如圖三看出PEN線(xiàn)上的電流值遠(yuǎn)大于相線(xiàn)電流,用電設(shè)備的外殼會(huì)產(chǎn)生嚴(yán)重的電位差,在正常狀態(tài)下,外殼帶電問(wèn)題更為嚴(yán)重。故,采取如下措施:(1)在三相電路中,應(yīng)盡量合理分配單相用電負(fù)荷,基本保證用電負(fù)荷的對(duì)稱(chēng)性,避免在三相電路中隨意亂接亂掛單相用電設(shè)備。(2)三相負(fù)荷性質(zhì)不同時(shí),應(yīng)采用專(zhuān)線(xiàn)專(zhuān)供方式,不能任意混接在三相同一低壓配電線(xiàn)路中。(3)將TN-C系統(tǒng)改為T(mén)N-S系統(tǒng)或TN-C-S系統(tǒng),如圖五、圖六。采用三相五線(xiàn)制,單相三相制供電方式。TN-C-S系統(tǒng)是在TN-C系統(tǒng)的后面,部分地或全部采用TN-S系統(tǒng),設(shè)備的外露可導(dǎo)電部分接PEN線(xiàn)或接PE線(xiàn)。由圖(六)看出:它是TN-C系統(tǒng)與TN-S系統(tǒng)的組合,它兼顧了TN-C系統(tǒng)與TN-S系統(tǒng)的優(yōu)點(diǎn),因此這種系統(tǒng)比較靈活,經(jīng)濟(jì)實(shí)用,應(yīng)用日益廣泛。4、結(jié)束語(yǔ)綜上分析可知:無(wú)論TN-C系統(tǒng)、TN-S系統(tǒng)、TN-C-S系統(tǒng)都必須注意以下幾個(gè)問(wèn)題:(1)N線(xiàn)上不得裝設(shè)開(kāi)關(guān)熔斷器,N線(xiàn)的連接點(diǎn)必須牢固可靠,導(dǎo)線(xiàn)截面必須滿(mǎn)足機(jī)械強(qiáng)度及載流量的要求,否則不僅造成人身觸電危險(xiǎn),而且會(huì)造成中性點(diǎn)偏移,引發(fā)事故。(2)合理調(diào)整和分配單相用電設(shè)備的負(fù)荷及負(fù)荷性質(zhì),否則會(huì)使流過(guò)N線(xiàn)電流過(guò)大,造成N線(xiàn)燒毀或熔斷。若為保證足夠的N線(xiàn)截面,勢(shì)必增加一定投資。(3)定期檢查N線(xiàn)及工作接地線(xiàn),按期進(jìn)行測(cè)量中性點(diǎn)接地電阻。(4)PE線(xiàn)路必須設(shè)置多處接地即重復(fù)接地。(5)裝設(shè)漏電保護(hù)開(kāi)關(guān)。參考文獻(xiàn):[1]劉介才.供配電技術(shù)[M].北京:機(jī)械工業(yè)出版社,2002.[2]胡翔駿.電路基礎(chǔ)[M].北京:高等教育出版社,2004.[3]陳小虎.工廠供電技術(shù)[M].北京:高等教育出版社,2001.[4]陳菊紅.電工基礎(chǔ)[M].北京:機(jī)械工業(yè)出版社,2000.作者簡(jiǎn)介:高來(lái)明(1949),男,河北唐山人,副教授,國(guó)家注冊(cè)安全評(píng)價(jià)師,國(guó)家注冊(cè)安全工程師繼續(xù)教育師資資格,主要從事電氣工程教學(xué)與科研及安全教育培訓(xùn)工作。
信息發(fā)布:廣州名易軟件有限公司 http://www.jetlc.com
|